Action > Structure change commands

The following structure change commands are available:

SettingDescription
ElemNdB Change the start node of an element
ElemNdE Change the end node of an element
ActOn Activation of an element series
ActOff Deactivation of an element series
ElemK Modify the cross section properties Ax, Iy, Iz during calculation for a series of elements  with using a multiplication factor.
Note: The values Ay, Az, and Ix describing shear behavior cannot be modified at element level. If required, they must be modified on cross-section level in the Modeler (GP)  or in Properties > Cross-sections. These modifications are always valid for the complete calculation run.
ElemHinge Assigning hinges to element